CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

Extinguishing Agent Release Systems

Agent Release Controller AS4214:2018

Products » Panels, Networking & Utilities Software » Extinguishing Agent Release Systems
Pertronic

ARC2 Agent Release Controller

Datasheet
Manual
ENQUIRE ABOUT THIS PRODUCT

The Pertronic Extinguishing Agent Release Controller (ARC2) is the central component of the Pertronic Extinguishing Agent Release System. The system is designed to control gas flood equipment. It may also be used to control other fire suppression systems.

The ARC2 is designed for installation in a fire panel. This can be a Pertronic F220©, F100A, F16e, or a third-party fire panel.

The controller monitors the fire panel for alarm signals. In the default “Double-Knock Auto” mode, the ARC requires two separate alarm signals in order to activate the agent discharge process. In “Single-Knock Auto” mode, the agent discharge process is triggered by a single alarm signal.

The agent discharge process can also be activated by manually activating the yellow call point on any connected control station (ACS2 or LCS2).

A single fire panel may be factory-fitted with multiple Extinguishing Agent Release Controllers. Each controller requires one Pertronic Agent Control Station, which is mounted on or near the fire panel.

Features

  • Provides an RS-485 bus for connection with an Agent Control Station and up to nine Local Control Stations
  • Programmable Features:
    • Alarm Input (“Single Knock” or “Double Knock”)
    • Auto Discharge Delay
    • Manual Discharge Delay
    • Release Output Hold Time
    • Pressure Switch Feedback
    • Low Pressure Fault Input
  • On-board System Isolate switch
  • Supervised Outputs:
    • Detonation
    • Dual stage two-wire dual polarity sign output
    • Two-wire “System Inoperative” sign output
  • Non-Supervised Outputs:
    • Activation Stage 1
    • Activation Stage 2
    • Agent Released
    • Agent Release System Fault
  • A Pertronic agent release system must include one Agent Release Controller

Ordering Information

Product Code

Description

ARC2

Agent Release Controller AS4214:2018

ARC2-CC

Agent Release Controller AS4214:2018; with conformal coating


Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL