2351TEM

Conventional multi-criteria detector with a photoelectric smoke sensor and a rate of rise heat sensor with 58 °C fixed (static) threshold

2151BPI

Conventional photoelectric smoke detector

2351E

Conventional photoelectric smoke detector

4351E

Conventional heat detector with 78 °C static (fixed) temperature threshold

5351E

Conventional rate of temperature rise heat detector with 58 °C static (fixed) temperature threshold

5351TE

Conventional heat detector with 58 °C static (fixed) temperature threshold

IHD*-V

NZS 4512:2010-compliant indicating heat detectors with static (fixed) temperature threshold at 57 °C (blue dot) or 77 °C (yellow dot)

IHD*E-V

NZS 4512:2010-compliant indicating heat detectors with protective encapsulation. 57 °C (blue dot) or 77 °C (yellow dot)

IHD*R-V

NZS 4512:2010-compliant indicating heat detector with terminals for remote indicator. 57 °C (blue dot) or 77 °C (yellow dot)

IHD*EK-V

Encapsulated indicating heat detector & cable for harsh environments. Static (fixed) temperature threshold: 57 °C (blue) or 125 °C (black)

IHD*EAR-V

Alkaline-resistant encapsulated indicating heat detectors. 57 °C (blue dot) or 77 °C (yellow dot)

HD*-V

NZS 4512:1997 indicating heat detectors, with or without encapsulation. Static (fixed) temperature threshold: 57 °C (blue) or 77 °C (yellow)

HD

NZS 4512:1997-compliant non-indicating heat detectors with static (fixed) temperature threshold at 57 °C (blue dot) or 77 °C (yellow dot)

2W-B

2-wire conventional photoelectric smoke detector

2WT-B

Multi-criteria detector, 2-wire, with photoelectric smoke sensor and heat sensor with 58 °C fixed (static) temperature threshold

2WTA-B

Multi-criteria detector, 2-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed (static) threshold, and alarm sounder

4W-B

4-wire conventional photoelectric smoke detector

4WT-B

Multi-criteria detector, 4-wire, with photoelectric smoke sensor and heat sensor with 58 °C fixed (static) threshold

4WTR-B

Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed (static) threshold, and relay

4WTAR-B

Multi-criteria detector, 4-wire, with photoelectric smoke sensor, heat sensor with 58 °C fixed (static) threshold, sounder, and relay

2012J

AS 3786-compliant domestic photoelectric smoke detector with sounder and form C relay

2012/24AUS

AS 3786-compliant domestic photoelectric smoke detector with sounder, form C relay, and battery

PC614

Conventional carbon monoxide (CO) and rate-of-temperature-rise heat detector. Suitable for detecting slow-smoldering and fast-flaming fires.

DETREM

Remote LED indicator unit

RMK400AP-IV

Recessed mounting kit for detectors, ivory