CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

Modules

Loop Relay

Products » Detectors, MCPs & Modules » Modules
Pertronic

F100LRU Loop Relay

Datasheet
Manual
ENQUIRE ABOUT THIS PRODUCT

The Pertronic Analogue Addressable Loop Relay provides four individually addressable output channels, controlled over an analogue addressable circuit (loop) by a Pertronic fire panel such as the Pertronic F220 or F100A.

Each output channel provides:

» A switched, supervised output providing 24 volts dc when activated, and
» A voltage-free relay contact

On each output channel, the supervised output and the voltage-free contact are activated simultaneously.

The supervised 24 volt dc output may be powered from the analogue addressable loop or from an external power supply. The load circuit connected to this output is supervised for short-circuit and open-circuit wiring faults.

The voltage-free relay contacts may be individually configured as normally open or normally closed.

The loop relay has two configurable output settings. When configured for “steady-only” operation, each active output stays on until de-activated by the fire panel. With pulsing enabled, the fire panel can activate each individual output in steady or pulsing mode (3.5 sec on, 12.5 sec off).

The loop relay has a built-in isolator. If the loop relay detects a short-circuit in the signalling circuit (loop) cable, the isolator disconnects the shorted segment. This ensures that the loop relay continues to communicate with the fire panel over the undamaged side of the loop circuit.

A single short-circuit or open-circuit fault will not prevent correct operation of the loop relay.

Features

  • Analogue addressable control module with four individually addressable output channels
  • Each output channel provides:
    • One voltage-free relay contact, configurable as normally open or normally closed, and
    • One switched supervised output providing 24 volt dc at up to 100 mA (loop powered) or 1 amp (externally powered)
  • Solenoid interface available for supervising external cabling to solenoids and similar loads
  • Up to 24 AA Loop Relays (a total of 96 outputs) may be connected to a Pertronic analogue addressable loop, subject to availability of power
  • The loop relay may be powered from the analogue addressable signalling line circuit (loop) or from an external isolated power supply
  • The integral short circuit isolator maintains normal operation with a single break or short-circuit in the analogue addressable loop
  • The loop address is programmed with direct-dial decade address switches
  • The loop relay is able to report the following fault types to the fire panel:
    • Isolator activation
    • Loss of external power supply
    • An open circuit on the PS Fault input
    • A short circuit or open circuit on any of the four supervised outputs, when that output channel is inactive
  • Configurable output modes:
    • All outputs steady (continuous) activation only
    • Each output may be steady or pulsing (on-off)
  • The loop relay uses four loop addresses when configured in steady mode, or eight loop addresses when pulsing mode is enabled
  • The loop relay is an optional component of Pertronic analogue addressable fire panels
  • The loop relay may be mounted remote from the fire panel. For this purpose the Pertronic AALRESC enclosure accommodates two loop relay modules
  • FPANZ listing number PI/634

Ordering Information

Product Code

Description

F100LRU

AA Loop Relay Board 4 Relays, V3.07


Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL