CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

Explosive Atmosphere Detection

Galvanic Isolator Interface

Products » Detectors, MCPs & Modules » Explosive Atmosphere Detection
Pertronic

ISGAIFNZSSAP Interface

Datasheet
ENQUIRE ABOUT THIS PRODUCT

The Pertronic Galvanic Isolator Interface (ISGAIFNZSSAP) connects a galvanically isolated detection circuit to a Pertronic conventional detection zone. The interface may be used with a conventional Pertronic fire alarm control panel (F1, F4, F16e), or a Pertronic loop responder.

The interface performs two functions:

  • Translates signals from intrinsically safe devices to trigger the appropriate response in a Pertronic conventional detection zone
  • Compensates for level changes introduced by the Galvanic Isolator

The Pertronic Galvanic Isolator Interface is compatible only with NZS 4512:2010 detection circuits. It does not support NZS 4512:1997 detection circuits.

Features

  • Interfaces one conventional detection zone with a Pepperl + Fuchs KFD0-CS-Ex1.51P Galvanic Isolator connected to conventional detection devices
  • Suitable for Pertronic NZS 4512:2010 20 Volt (nominal) conventional circuits, including F1, F4, F16e, and Loop Responder
  • Powered from conventional zone +20 Volt dc output
  • Translates Orbis intrinsically-safe (IS) detector levels and MCP activation to Pertronic M-voltage levels
  • May be used with a mix of Orbis and System Sensor EIS series IS detectors
  • Works with normally-closed type intrinsically-safe MCPs (contact goes open when activated)
  • LED indications for NORMAL (green), ALARM (red), and DEFECT (yellow)
  • Label on the product shows connection diagram
  • Maintains the integrity of fire alarm control panel Earth-Defect supervision
  • On-board indicator shows current and historic defects
  • Missing 20 V, 0 V, or M causes a defect
  • Wiring open- or short-circuits between the Interface and the Galvanic Isolator trigger a Defect
  • 35 mm DIN-rail mounting

NOTE

The Galvanic Isolator Interface does not support NZS 4512:1997 circuits. In these circuits, an open circuit in the detector cabling would trigger a (non-indicating) heat or MCP alarm condition at the panel.

 

WARNING: The information on this website must not be treated as complete instructions for the design, construction, installation, commissioning, or maintenance of systems in hazardous areas. Cabling and fire system devices in hazardous areas must be designed and installed by properly qualified persons, in accordance with all applicable standards and regulations.

Ordering Information

Product Code

Description

ISGAIFNZSSAP

Galvanic Isolator Interface


Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL