CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

Detectors

Linear Heat Detection Cable

Products » Detectors, MCPs & Modules » Detectors
Pertronic

Pertronic-Anbesec LHD Cable

Datasheet
ENQUIRE ABOUT THIS PRODUCT

Pertronic-Anbesec linear heat detection (LHD) cable is a heat sensing device with a fixed temperature alarm threshold.

The cable consists of two twisted steel wires separated by heat sensitive insulation. The insulation melts at a pre-determined temperature, allowing the wires to contact each other and create a short circuit. When correctly connected to a Pertronic fire panel, the LHD cable triggers an alarm signal when the insulation melts.

Pertronic-Anbesec LHD cable may be connected to all current Pertronic fire panels including

  • F1
  • F4
  • F16e
  • F100A
  • F220

LHD cable sensitivity is not affected by installation temperature or the length of cable heated by a fire.

Features

  • Available with integral catenary wire
  • Compatible with Pertronic conventional and analogue addressable fire panels
  • Typically 1,600 metres of cable may be connected to a Pertronic conventional detection zone
  • No adjustments required
  • Supplied on 200, 400 and 500 metre drums
  • Standard (non-catenary) LHD cable also available on 500 metre drums
  • Pertronic-Anbesec LHD cable is UL listed under “UL 521 Heat Detectors for Fire Protective Signaling Systems” (referenced in NZS 4512:2010 section 216.1)
  • FPANZ listed

NOTE: This information applies to NZS 4512 versions of Pertronic fire panels and modules. For information about connecting LHD cable to our export products, please contact your nearest Pertronic office.

Ordering Information

Product Code

Description

LHDCATIC-88C-200

Linear Heat Detection Catenary Indoor PVC Sheath Cable NMS1001-88C-G in 200m Drums

LHDCATIC-88C-400

Linear Heat Detection Catenary Indoor PVC Sheath Cable, NMS1001-88C-G, in 400m drums

LHDSIC-88C-200

Linear Heat Detection Standard Indoor PVC Sheath Cable NMS1001-88C in 200m Drums

LHDSIC-88C-500

Linear Heat Detection Standard Indoor PVC Sheath Cable, NMS1001-88C, in 500m drums

LHDCATIC-68C-200

Linear Heat Detection Catenary Indoor PVC Sheath Cable NMS1001-68C-G in 200m drums

LHDCATIC-68C-400

Linear Heat Detection Catenary Indoor PVC Sheath Cable, NMS1001-68C-G, in 400m drums

LHDSIC-68C-200

Linear Heat Detection Standard Indoor PVC Sheath Cable NMS1001-68C in 200m drums

LHDSIC-68C-500

Linear Heat Detection Standard Indoor PVC Sheath Cable, NMS1001-68C, in 500m drums


Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL