CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

Amplifiers

20W 12V Amplifier

Products » Alarm (Alerting) Devices » Amplifiers
Pertronic

EVAC20W12V Amplifier

Datasheet
Installation Note
ENQUIRE ABOUT THIS PRODUCT

The Pertronic 20W Amplifier (EVAC20W12V) is an evacuation amplifier with integral evacuation tone and message generator, together with a fault detection system. It is designed for use in emergency warning systems with supervised 100 Volt Line distribution systems. The amplifier delivers up to 20 Watts of audio power to the 100 Volt line.

The EVAC20W12V generates an evacuation tone with a voice message as specified in NZS 4512:2010. The amplifier is controlled by the BELL output of a fire alarm panel such as the Pertronic F1 or F4.

When in standby, the 100 Volt line is connected to the BELL circuit. This allows the fire alarm panel to detect short or open circuit faults on the 100 Volt line. The BELL circuit drives a small dc current through the 100 Volt line, which must be terminated with a suitable end of line resistor. It is important to note that every speaker connected to the supervised 100 Volt Line must be specially designed for emergency warning systems, with each speaker incorporating a DC blocking capacitor.

Features

  • Generates the ‘Evacuation’ tone with verbal messages as specified by NZS 4512:2010
  • Can be directly mounted into the Pertronic F1 or F4 Conventional Fire Alarm panels, but can be used with any 12V Fire Alarm system
  • Activated when the BELL circuit voltage polarity reverses to the ‘Alarm’ state
  • In the ‘Normal’ state, the amplifier draws practically no current (less than 0.2 μA) and appears transparent to the Fire Alarm panel
  • The 100 Vrms line is internally connected to, and monitored by the panel’s BELL circuit 
  • The amplifier’s 100 Vrms line is short-circuit protected and is capable of driving up to 20W (13.7 Vdc supply) into connected PA loud speakers, eg. Pertronic PSS1 and PSSB401

Ordering Information

Product Code

Description

EVAC20W12V

Evac Amplifier 20W 12V


Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL