CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

This product is available under the following categories

  • Discontinued Products: Waterflow Devices

Sprinkler Fire Brigade Alarm Type Y - Discontinued Product

Pertronic

SGDFBA-Y Brigade Alarm

  • Manual
ENQUIRE ABOUT THIS PRODUCT

The Pertronic Sprinkler Fire Brigade Alarm SGDFBA monitors one or more sprinkler-activated switches. In the event of a sprinkler system activation, the Sprinkler Fire Brigade Alarm generates a fire alarm signal and triggers an evacuation.

To call the fire brigade, the SGDFBA sends a fire alarm signal to an ASE, CTU, or NAD transmitter via an RS-485 link using the LTX/SGD protocol.

To trigger an evacuation, the SGDFBA activates its SPR MON output, which signals a sprinkler activation to the fire panel.

The SGDFBA may be powered by the transmitter. Alternatively, it may be powered from an external 12 Vdc or 24 Vdc power supply.

Internal software provides accurate detection of Fire and Defect conditions, while rejecting brief pressure surges due to nuisance conditions such as water supply maintenance work. This includes a mechanism to address sprinkler system chugging, where cyclic water flow and pressure variations may occur after sprinkler head operation.

An optional Display Relay Board provides clean contact outputs for Fire and/or Defect.

The Pertronic SGDFBA is approved and listed on the sprinkler register.

Features

  • Automatic latching of the Fire signal
  • Powered by either the monitoring transmitter or a local power supply
  • Interfaces with the transmitter via RS-485 using LTX/SGD protocol (standard or multi-drop)
  • Transient surge rejection algorithm
  • Anti-chugging pulse counter
  • Sprinkler operated local buzzer (piezo sounder) output
  • Front panel LED indicators for Fire, Defect, and Normal
  • External BCO (Bell Cut Off)
  • Internal BCO
  • External Defect input
  • Anti-Interference input
  • Test and Isolate switches
  • Latching Defect indication
  • Door Closed alarm

Ordering Information

Product Code

Description

Availability

SGDFBA-Y

SGDFBA Type Y

Discontinued


Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL