CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

This product is available under the following categories

  • Aspirating Smoke Detection

Stand-Alone Aspirating Smoke Detector

Pertronic

FAAST LT-200 Conventional

  • Datasheet
  • Manual
  • Installation Note
ENQUIRE ABOUT THIS PRODUCT

The FAAST LT-200 Aspirating Smoke Detector provides smoke detection in normal sensitivity (Class C) applications. It is well-suited for applications where maintenance is difficult, where point or beam smoke detection is not appropriate, or where aesthetic considerations rule out traditional smoke detection methods. It is also suitable for smaller high-sensitivity (Class A or B) applications.

The LT-200's internal fan draws air from the monitored environment, through an external sampling pipe, into the detection chamber. The air flow is monitored by ultrasonic flow sensors. An LED display on the LT-200's front panel provides real-time indication of flow conditions.

Three variants of the FAAST LT-200 analogue addressable aspirating smoke detector are available:

  • Single channel, single sensor
  • Single channel, dual sensor, for double-knock
  • Dual channel, with separate fan, flow monitoring system, and a sensor for each channel

Configurable options include alarm thresholds, external input, and the auxiliary relay. The LT-200 may be configured with separate alarm thresholds for day, night, and holiday (or weekend), including automatic adjustment for daylight saving. The external input may be configured to trigger a fault condition, disable the LT-200, reset the LT-200, or silence the sounder output.

The detector provides alarm, pre-alarm and fault relays and an optional auxiliary events relay. Relays may be configured as latched or non-latched.

LT-200 detectors may be configured using the PipeIQ system design and configuration application. PipeIQ also has tools for pipe network design, and aspirating system installation, and commissioning. This free software runs on Windows 7, 8, and 10.

Features

  • Single & dual channel models with independent channels including fan, sensor and flow monitoring
  • Detection chamber optimised for Class C applications, with high output infra-red LED and high sensitivity receiver
  • Configurable sensitivity: Nine settings from 0.07 %Obs/m to 6 %Obs/m
  • Pre-alarm function for graduated alarm thresholds
  • Ultrasonic airflow sensing with expanded monitoring range
  • Day / Night / Weekend mode enables pre-set thresholds based on routine changes in the environment’s usage
  • A single device covers up to 2,000 m² according to national design regulations
  • One sounder output per channel
  • Very quiet fan, as low as 26 dB(A)
  • Multiple event logging up to 2244 events
  • User friendly air flow pendulum graph for verification of pipe network functionality
  • Reusable, easily replaced filter
  • Electronics protected from air flow and accidental damage during installation or maintenance
  • Easy access to filter(s) and sensor(s) for routine maintenance
  • IP65 enclosure
  • PipeIQ™ software provides intuitive system layout and configuration in one package

Click here to download the white paper: Aspirating Smoke Detector Pipe Installation

FAAST LT-200 Set-Up and Trouble-Shooting Guide

Ordering Information

Product Code

Description

Availability

FL0111E-HS

FAAST-LT Conventional Single Channel ASD

FL0112E-HS

FAAST-LT Conventional Single Channel, 2 detector ASD

FL0122E-HS

FAAST-LT Conventional Dual channel Detector

Discontinued


Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL