CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

Mimics, Repeaters & Interfaces

Text (Nurse Call, Printer, Pager) Interface for Stand-Alone Fire Panels

Products » Panels, Networking & Utilities Software » Mimics, Repeaters & Interfaces
Pertronic

SPIB Text Interface

Datasheet
Manual
ENQUIRE ABOUT THIS PRODUCT

Product Overview

The Pertronic Text Interface (SPIB-NCPP) exports selected fire system events as serial text, suitable for printers, paging systems, nurse-call paging systems, or other text-based systems.

The interface connects to the RS-485 Mimic Bus of any Pertronic analogue addressable fire panel. It examines fire panel event data and converts selected event types into text. Any event that appears on the fire panel LCD display can be converted into text.

The output message format is defined using a template. The template specifies the format of event messages, and is readily customised using a personal computer.

Special escape codes act as place-holders for event-specific information such as the event type or event source. This information can be formatted to suit the requirements of the target system, whether it recognises free-format, fixed-width or character-delimited text.

The template can include literal text. This includes ASCII formatting characters such as tabs, form feeds, and carriage returns.

The output is transmitted via RS-232 or RS-485. The data rate is configurable from 300 bit/s to 230.4 kbit/s.

The Pertronic Text Interface can be mounted inside a fire panel, or at a remote location.

A galvanic isolation system in the interface isolates the fire alarm control panel’s RS-485 Mimic Bus from all other connections to the interface.

Features

  • Recommended for stand-alone Pertronic F220 and F100A fire alarm control panels
  • Provides all data accessible via the fire alarm control panel’s LCD display
  • Configurable using a PC running a terminal emulation program via the USB port
  • Configurable options include
    » RS-232 or RS-485 serial output
    » Data rate: 300 bit/s to 230,400 bit/s
    » Heartbeat output if no other messages are generated in a specified time
    » Output throttling specifies a minimum time between output messages
    » Large range of time and date formats
  • Versatile formatting capabilities allow the text output to be tailored for a large range of external systems
  • Powered from the RS-485 Mimic Bus
  • Electrically isolated from the fire alarm control panel’s RS-485 Mimic Bus
  • Optional supervision of the connection and communication between the Text Interface and the alarm control panel using mimic emulation
  • On-board LEDs provide diagnostic information
  • Also compatible with the F120A fire panel RS-485 mimic bus

Ordering Information

Product Code

Description

SPIB-NCPP

Text (Nurse Call, Printer, Pager) Interface for Stand-Alone Fire Panels


Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL