CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

Software Applications

Messaging Interface for FireMap

Products » Panels, Networking & Utilities Software » Software Applications
Pertronic

FireMap Pager

Datasheet
Manual
ENQUIRE ABOUT THIS PRODUCT

Pertronic FireMap Messaging Interface (FIREMAP-PAGER) is a software extension that enables Pertronic FireMapĀ® systems to automatically send email, pager, or printed messages in response to pre-determined events.

The interface may be configured with multiple messages. Each message may include any mix of pre-defined text and FireMap database field values, such as device descriptors and event types. For example, a message might say that an alarm occurred at a certain time, initiated by a smoke detector in a certain part of a facility.

Each message may be initiated by a specific event, such as an alarm or fault, from any device, zone, or fire panel. Triggering events include inputs to analogue addressable devices such as loop responders or FireMap Ethernet gateways (FMEGATE). The system can be configured to send multiple messages in response to a single initiating event.

Each message can be individually tested.

Used in conjunction with an external SMS interface, Pertronic FireMap Messaging Interface may be configured to trigger text (SMS) messages.

The interface has a suspend function which halts messaging output for a pre-configured time period. This may be used, for example, to prevent transmission of nuisance messages during fire system testing or maintenance. The interface automatically returns to normal operation after the pre-configured suspend time period.

Features

  • Easy to use configuration screens
  • Flexible message editing system
  • Practically unlimited number of messages
  • Each message may be configured for email, pager, or printer
  • Message Test feature allows the user to manually trigger a sample of any selected message
  • Messages are transmitted via TCP/IP (Ethernet), RS-232, or a printer port
  • Messages may be triggered by any event reported by any analogue addressable device
  • Automatic start-up on reboot
  • Configurable suspend period for pre-planned down-time
  • Configurable automatic retries for failed connections
  • Full control over which connections are enabled or disabled on startup
  • Simple integration with existing Pertronic FireMapĀ® installations
  • Configuration settings may be exported, allowing an existing FIREMAP-PAGER installation to be cloned or reconstructed by importing the saved configuration settings

Notes:

1. FireMap Pager v3.xx is compatible only with Pertronic FireMapĀ® v3.xx or later. For earlier versions, please contact your nearest Pertronic office.

2. Messages are not able to be triggered by Modbus register values (NMOs).

Ordering Information

Product Code

Description

FIREMAP-PAGER

Pager Interface for FireMap Graphics System


Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL