CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

Networking

Network Card

Products » Panels, Networking & Utilities Software » Networking
Pertronic

NETCARD Network Card

Datasheet
Manual
ENQUIRE ABOUT THIS PRODUCT

The Pertronic Network System can connect up to 99 nodes using the two-wire RS485 data communication loop. Each node may have a Pertronic F100A, F120A fire alarm control panel, network control unit, network display unit, mini mimic, or FireMap connection. The network is fault tolerant so that a single break or short-circuit anywhere in the communication loop will not compromise the operation of the system. A computer may be connected to any of the network cards to configure and program the network.

Panel-to-Panel Mapping:

A device at one panel may be mapped as a network input to one or more of the other panels for ‘Alarm’ indication or to activate system relays or other mappable outputs. For example, a detector on Panel 3 can be mapped to Panel 5 to activate the evacuation sounders and, for example, Relay 23 on Loop 2.

Up to 64 network inputs may be used for F100A fire alarm control panels, and up to 128 network inputs for F120A fire alarm control panels.

Network Card may be supplied with either “Panel” or “Supervisory” firmware.

Network Card (NETCARD): with “Panel” firmware may be configured as either:

  • Panel Network card: Interfaces the system information from individual Fire Panels to the network.
  • Network LED mimic card: Drives up to 8 LED display mimics using either 12-Way smart LED mimic or LED address controller (LAC) boards.
  • Up to 128 LEDs may be displayed.
  • The ‘BCO’ and ‘Evacuation’ key-switches at the 12-Way LED mimic or LAC boards operate globally around the network.
  • The global system LEDs operate normally to reflect the network status

Network Card – NCU (NETCD-NCU): with “Supervisory” firmware:

  • Can connect to 1 x network control unit (NCU), up to 8 x network display units (NDU), 1 x FireMap connection or 1 x pager system.

Network Display Unit (NDU):

  • Displays all alarms, network inputs and pre-alarms by device descriptor and panel location (Alarm, Network and Pre-Alarm queues)
  • Allows ‘Reset’ and ‘Isolation’ of alarms and network inputs from the relevant queue.
  • Isolate queue: indicates all devices that have been isolated across the network.
  • Network Fault queue: indicates fault conditions specific to the network.
  • Panel Fault queue: indicates the panels, which have fault conditions and the number of faults.
  • System Event queue: displays system events eg. ‘Silence Alarms’, ‘Evacuate’, etc. for each panel.

Network Control Unit (NCU):

  • Includes all of the functions of the NDU plus the ability to select any panel on the network and control its functions directly.
  • All menu items of the selected panel may be accessed – status, history log, etc. 

Pager:

  • Queue events may be configured as outputs to a paging system or network printer

Ordering Information

Product Code

Description

NETCARD

Network Card - F100/F120 Panels/LED Mimics


Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL