CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

Networking

F220 & Net2 Network System

Products » Panels, Networking & Utilities Software » Networking
Pertronic

Net2 Network

Datasheet
Manual
ENQUIRE ABOUT THIS PRODUCT

The Pertronic Net2 Network connects multiple fire panels, Net2 Network Control Units (Net2 NCU) and Net2 remote displays into a single fault-tolerant system.

On a Pertronic Net2 Network:

  • Any or all connected fire panels can be controlled and monitored from any Net2 Network Control Unit
  • Information from any connected panel(s) can be viewed on any Net2 NCU or Net2 remote display
  • Events anywhere on the network can trigger or influence events at any connected fire panel

A Pertronic Net2 Network may include up to 133 Net2 Network Cards (“nodes”). Each network card may be configured to interface one of the following devices to the Net2 Network.

  • F220 fire panel (FP)
  • Modbus master device
  • Pertronic FireMap® work-station

A network may have multiple Modbus and/or FireMap interfaces.

In addition, a network card may connect with up to eight Net2 NCUs, each of which may provide full control and monitoring of any or all fire detection and alarm systems connected to the network.

Adaptive messaging in the Pertronic Net2 Network prioritises alarms and important control signals to ensure rapid transmission even under extreme network load situations.

Features:

  • Up to 100,000 panel-to-panel object mappings per Net2 Network System
  • 5,000 object mappings to any individual fire panel
  • 640 configurable network inputs per fire panel (multiple objects may be mapped to each input)
  • 359 logical inputs per fire panel
  • Supports zone numbers from 0 to 64,999
  • Bi-directional Modbus interface provides:
    -- 3,000 Boolean Nodal Mapping Objects (NMOs)
    -- Ability to map up to 8 timers from any FPs on the network to Modbus registers. (Multiple timers may be mapped to a single register. The total number of mapped timers must not exceed 8.)
    -- Mappable I/O watchdog
  • Plain text descriptors for network inputs, NMOs, NCUs, and remote displays (mini-mimics)
  • If the network watchdog system detects an error, it will deactivate any mappings affected by that error
  • Plug-in fibre-optic modules allow the standard network interface to support a mix of twisted-pair copper (RS-485) and/or fibre-optic network segments
  • The network is programmable from a single point using Ethernet-connected Pertronic FireUtils®. Upload times for typical networks:
    -- 34 nodes: Less than one minute
    -- 130 nodes: Less than five minutes
  • Automatic fault supervision system detects a range of faults including earth faults on copper segments, circuit breaks, and FP or node configuration changes
  • A single cable fault anywhere in the Net2 Ring Circuit will not interrupt network operation
  • Automatic system-wide clock synchronisation
  • Automatic clock adjustment for daylight saving
  • System time and date adjustable from any fire panel
  • Users can reset or disable individual loop devices, alarm routing, timers, logic blocks, and network inputs from any Net2 NCU
  • Loop devices can be tested from any Net2 NCU
  • Recent Network Event log, and FP logs, accessible from Net2 NCUs, FPs, and full function panel mimics
  • FP data logs downloadable to FireUtils® from any node
  • NET2CARD Linux OS diagnostic logs are available for analysis by Pertronic technical support engineers

Contact us to find out more about the Net2 Network System

Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL