CLICK to CALL US NOW
SEARCH
LOGIN
AUSTRALIA | USA | NZ

Home
Products
Panels, Networking & Utilities Software
Fire Alarm Control Panels
Analogue Addressable Panels
Conventional Panels
Networking
F220/Net2 Network
F120A & F100A Network
Software Applications
FireMap PC Graphics
Fire System Programming
Extinguishing Agent Release Systems
Equipment Cabinets
Mimics, Repeaters & Interfaces
Transmitters
Accessories
Tools and Test Equipment
Detectors, MCPs & Modules
Detectors
Analogue Addressable Detectors
Analogue Addressable Beam Detectors
Analogue Addressable Duct Detectors
Conventional Detectors
Conventional Beam Detectors
Conventional Duct Detectors
Flame Detectors
Linear Heat Detection
Detector Accessories
Bases
Analogue Addressable Bases
Conventional Bases
Manual Call Points
Analogue Addressable MCPs
Conventional MCPs
Modules
Aspirating Smoke Detection
Explosive Atmosphere Detection
Alarm (Alerting) Devices
Speakers
Sounders
VADs & Strobes
Sounder + Strobes
Amplifiers
AV Signs
Explosive Atmosphere
Mass Notification System
Wireless
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
Discontinued Products: Panels, Networking, & Software
Discontinued Products: Detectors, MCPs & Modules
Discontinued Products: Alarm (Alerting) Devices
Discontinued Products: Power Supplies
Discontinued Products: Waterflow Devices
News
Downloads
Tools
Battery Size Calculator
Loop Length Calculator
EA Series Text to Speech Tool
Order online
Pertronic SOS
Projects
About
Support
Sitemap
Building Product Information Requirements
Contact Pertronic
  • Home
  • Products
    • Panels, Networking & Utilities Software
      • Fire Alarm Control Panels
        • Analogue Addressable Panels
        • Conventional Panels
      • Networking
        • F220/Net2 Network
        • F120A & F100A Network
      • Software Applications
        • FireMap PC Graphics
        • Fire System Programming
      • Extinguishing Agent Release Systems
      • Equipment Cabinets
      • Mimics, Repeaters & Interfaces
      • Transmitters
      • Accessories
      • Tools and Test Equipment
    • Detectors, MCPs & Modules
      • Detectors
        • Analogue Addressable Detectors
        • Analogue Addressable Beam Detectors
        • Analogue Addressable Duct Detectors
        • Conventional Detectors
        • Conventional Beam Detectors
        • Conventional Duct Detectors
        • Flame Detectors
        • Linear Heat Detection
        • Detector Accessories
      • Bases
        • Analogue Addressable Bases
        • Conventional Bases
      • Manual Call Points
        • Analogue Addressable MCPs
        • Conventional MCPs
      • Modules
      • Aspirating Smoke Detection
      • Explosive Atmosphere Detection
    • Alarm (Alerting) Devices
      • Speakers
      • Sounders
      • VADs & Strobes
      • Sounder + Strobes
      • Amplifiers
      • AV Signs
      • Explosive Atmosphere
      • Mass Notification System
      • Wireless
    • Power Supplies
    • Waterflow Devices
    • Spare Parts
    • Historic Products
      • Panels, Networking, & Software
      • Detectors, MCPs & Modules
      • Alarm (Alerting) Devices
      • Power Supplies
      • Waterflow Devices
  • News
  • Downloads
  • Tools
    • Battery Size Calculator
    • Loop Length Calculator
    • EA Series Text to Speech Tool
    • Order online
    • Pertronic SOS
  • Projects
  • About
  • Support
  • Sitemap
  • BPIR
  • Contact

Analogue Addressable Detectors

IA Pinnacle High Sensitivity Smoke Detector, C Series

Products » Detectors, MCPs & Modules » Detectors » Analogue Addressable Detectors
Pertronic

7251CPI Detector

Datasheet
Installation Note
ENQUIRE ABOUT THIS PRODUCT

The 7251CPI C Series Pinnacle™ smoke detector is a high sensitivity intelligent addressable photoelectric detector for applications requiring sensitivity settings over and above the performance of standard photoelectric detector. It is designed for very early warning fire detection, and is suitable for protecting valuable assets and operational systems that must remain functioning at all times. The 7251CPI achieves detection levels up to approximately 100 times more sensitive than a standard photoelectric detector.

This detector features a smoke sensing chamber designed to detect smoke and diminish stray internal reflections that can cause nuisance alarms. These features were developed to satisfy stringent nuisance alarm immunity tests defined in the US smoke detector standard, UL 268 edition 7.

A suitably configured fire panel will display the location of any detector which has initiated an alarm, fault, or maintenance signal.

Features

  • Intelligent addressable (IA) communication with fire panel
  • Very early warning fire detection capability
  • Automatic drift compensation
  • Stable communication with excellent noise immunity
  • Fire panel may be configured with separate alarm, fault, and maintenance thresholds for each individual detector
  • Rotary address switches for setting the address on the intelligent addressable loop
  • Fire panel identifies active detectors by lighting up two red LEDs on the detector housing
  • LEDs briefly light up (“blink”) when the detector is polled
  • LED blink may be disabled via the fire panel configuration
  • Dual LEDs for visibility from all normal viewing angles 
  • Optional remote LED indicator available
  • Magnet test function activates detector and bypasses inbuilt delays to facilitate testing
  • Compatible with B501AUS, B501AP, and other System Sensor intelligent addressable bases
  • Compatible bases provide an optional anti-tamper feature that prevents removal of the detector without a tool
  • Compatible with Pertronic F100A, F220 and F120A fire panels
  • SAI Global StandardsMark listed to AS 7240.7:2004, certificate SMHK25312
  • FPANZ Listing PI/368

Ordering Information

Product Code

Description

7251CPI-W

IA Pinnacle High Sensitivity Smoke Detector, C Series, White, excl Base


Panels, Networking & Utilities Software
Detectors, MCPs & Modules
Alarm (Alerting) Devices
Power Supplies
Waterflow Devices
Spare Parts
Historic Products
DOWNLOAD TECHNICAL INFORMATION

Pertronic Industries Ltd
17 Eastern Hutt Road, Wingate
Lower Hutt 5019
PO Box 35-063, Naenae
Lower Hutt 5041
04 567 3229

Auckland Office
3 Gloucester Park Rd, Onehunga
Auckland 1061
09 633 0226

Christchurch Office
35 Buchanans Road, Hei Hei
Christchurch 8042
03 599 9136

ENGINEERING TOOLS
VIEW TERMS OF TRADE
DOWNLOAD TECHNICAL INFORMATION

SUBSCRIBE TO PERTRONIC NEWS

FIREBITS BY MAIL ENEWS BY EMAIL