Top Curve
Analogue Systems
22051EIS 22051EIS Photoelectric IS smoke detector
Y72221 Galvanic Isolator
IST200 Intelligent Translator Module
The 22051EISE analogue addressable photoelectric sensor is a plug in intrinsically safe smoke sensor combining an optical sensing chamber with analogue addressable communications. As an intrinsically safe sensor, the 22051EISE has been designed specifically to provide fire protection for most hazardous environments. The 22051EIS is used in conjunction with the Y72221 Galvanic Isolator and the IST200 Intelligent Translator Module.

  Conventional Systems
1151EIS ISGAIFNZ Galvanic Isolator interface
ISMTL5561 Galvanic Isolator
The Pertronic Industries’ Galvanic Isolator interface has been designed to provide a simple, cost effective solution for Hazardous Area installations. The interface is designed to work with the Pertronic (F4, F16e and Loop Responder) in combination with a Galvanic Isolator. The Galvanic Isolator separates safe and hazardous areas, with detection devices connected to the output of the Isolator.

1151EIS 1151EIS
1151EIS Intrinsically Safe Ionisation Smoke detectors use state-of-the-art sensing chambers and SMD circuitry for maximum reliability. These detectors are designed to afford open area protection and are for use in hazardous areas where potentially explosive atmospheres are likely to arise (confirm classification of equipment required with your responsible authority).

5451EIS 5451EIS
5451EIS is an Intrinsically Safe Rate of Rise detector with fixed temperature alarm. It uses state-of-the-art dual thermistor technology to provide maximum sensitivity. This detector is designed to afford open area protection and is for use in hazardous areas where potentially explosive atmospheres are likely to arise (confirm classification of equipment required with your responsible authority).

Pertronic Heat Detector HDB, HDBE, HDY, HDYE, HDBLK, HDBLKE
Pertronic Industries' fast response, fixed temperature, Heat Detectors protect against false activation caused by vibration or other transient impulses. Fully complies with NZS 4512:1997.

CPP CPP
Pertronic Industries' Manual Call Point is a high-reliability fire alarm activation device. Features include “Snapglaze” frangible element for improved user safety. Fully complies with NZS 4512:1997.

  Sounders Systems
E2SA105N-IS E2SA105N-IS
The A105N-IS is an IP66 ATEX certified Intrinsically  Safe Sounder which produces a loud (105dB(A) @ 1 metre) warning signal in a hazardous area.

BExDL15D BExDL15D, BExDL15E
The BExDL15D(/E) is a 15W 100V line PA loudspeaker, Flameproof & Dust ignition proof, ideal for hazardous environments.

BExL15D BExL15D, BExL15E
The BExDL15D(/E) is a 15W 100V line PA Flameproof loudspeaker ideal for hazardous environments.

E2SxL15EG E2SxL15EG
The E2x15EG is a 15W high output PA loudspeaker, ideal for hazardous environments with high ambient noise levels.

Shunt diode safety barrier
ISBMTL778 (a.c)
Shunt diode safety barrier used on 24V sounder circuits. Suitable for F16e, F100A, & F120A panels.

Shunt diode safety barrier ISBMTL765 (a.c)
Shunt diode safety barrier used on 12V sounder circuits. Suitable for F16, F4, & F1 panels.

Bottom Curve